国产成人无码精品久久久免费_亚洲女精品一区二区三区_海外免费人成视频x8x8在线观看_国内少妇毛片视频

 
混凝土應(yīng)變的測(cè)量
混凝土應(yīng)力的測(cè)量
混凝土溫度的測(cè)量
混凝土開(kāi)合度測(cè)量
巖石應(yīng)變量的測(cè)量
鋼筋應(yīng)力值的測(cè)量
滲透水壓力的測(cè)量
測(cè)壓管水壓力測(cè)量
水庫(kù)水位值的測(cè)量
錨索預(yù)應(yīng)力的測(cè)量
靜荷載承壓力測(cè)量
結(jié)構(gòu)表面應(yīng)變測(cè)量
結(jié)構(gòu)位移量的測(cè)量
結(jié)構(gòu)傾斜量的測(cè)量
剛性構(gòu)件應(yīng)變測(cè)量
土體應(yīng)變量的測(cè)量
土體應(yīng)力值的測(cè)量
土體多點(diǎn)位移測(cè)量
土體多點(diǎn)沉降測(cè)量
土體分層沉降測(cè)量
地基多點(diǎn)位移測(cè)量
地基水平位移測(cè)量
地基垂直位移測(cè)量
自動(dòng)采集測(cè)量數(shù)據(jù)
 
? Strain Gages
? Piezometers
? Water Pressure(Water Level)
? Soil Pressure
? Displacement
? Temperature
? Inclinometers
? Settelment
? Testing Meters
? Calibration Devices
? Datalogger Devices
? Datalogger System
? Cables and Attachments
? Mud-Rock Flow Monitoring System
 
On Jan, 2009, our company has moved to the new address where locates in the city-centre district of Nanjing. The improvement of our working environment will propel the development of our company. Furthermore, the convenient traffics help us to fulfill a better after-sale service. NGN Instrument, Inc. expects your visiting!
 
Products
 

Model GL-1A Weir Transducer

 

1  Application

Model GL-1A Weir Transducer is applicable to measure the water level of weir notch for the river, pool, water reservoir, dam, etc. It is the device that used for monitoring and measuring the changing of flow. This device adopts the magnetostrictive transducer. It has the advantages as high resolution, high accuracy, high stability, high reliability, short response time, long lifetime, etc.

The main features are: measurement in straight-line, output with resolute position, non-contact continuously measurement, free of abrasion, free of second calibration, no needs to maintain carefully, multi-choice with input-output (could be Voltage/Current analogue or RS485 digital signal), easy for installation, etc.

 

2   Technical Specifications

 

                  GL-1A

Measurement Range (mm)

  0??700

Least Reading

 ??0.2

Accuracy (F.S)

??0.1%

Signal Output

0??5V??4??20mA??RS485

Insulation Resistance

??50??

3  The Theory of Operating

3.1 Constitution

Model GL-1A Weir Transducer consists of antifouling tube, top lid, magnetostrictive transducer, spirit bubble, cable, etc. (also see Fig.1)

3.2 Mechanism

The transducer mainly consists of the measurement rod, electronic part and the non-contact magnetic float ball. Inside the rod there is magnetostrictive wire (Guide wire). And the measurement rod is made of stainless steel tube that is not magnetic thus the guide wire is reliably protect. During working, the electrical circuit generates an initial pulse and the pulse generates the rotating magnetic field in the direction of the guide wire when it is transferred in the guide wire. And when this magnetic field meets the permanent magnetic field in the floating ball, then magnetostrictive effect generates so that the guide wire will be twisted. This twist is identified by the electronic part and converted further to the corresponding current pulse. By measuring the time different of these two pulses, the measured water level value can be pr??cised obtained.

4  Reading and Calculation             

4.1 Reading

Using Model GN-103A Readout Box can directly read the modulus value F manually; using Model MCU-32 Distributed Modularization Automatic Measuring Unit is able to collect data automatically.                                                 

4.2 Calculation                       

                                                        ??L= K (F??F0)

Herewith,

??L: the changing value of the water level in the weirnotch with the unit of mm;

F: Real time measured value with the unit of F;

F0: Reference value with the unit of F;

K: Transducer coefficient with the unit of mm/F;

4.2.1 If the changing value of water level ??L is positive then it means the water level is increased relative to the reference value.

4.2.2 If the changing value of water level ??L is negative then it means the water level is decreased relative to the reference value.                                                           

4.2.3 In the normal working situation, the temperature influence is very small to the system. The temperature correction coefficient is smaller than the least reading, thus the influence of temperature can be ignored.

 

 