国产成人无码精品久久久免费_亚洲女精品一区二区三区_海外免费人成视频x8x8在线观看_国内少妇毛片视频

 
混凝土應(yīng)變的測量
混凝土應(yīng)力的測量
混凝土溫度的測量
混凝土開合度測量
巖石應(yīng)變量的測量
鋼筋應(yīng)力值的測量
滲透水壓力的測量
測壓管水壓力測量
水庫水位值的測量
錨索預(yù)應(yīng)力的測量
靜荷載承壓力測量
結(jié)構(gòu)表面應(yīng)變測量
結(jié)構(gòu)位移量的測量
結(jié)構(gòu)傾斜量的測量
剛性構(gòu)件應(yīng)變測量
土體應(yīng)變量的測量
土體應(yīng)力值的測量
土體多點(diǎn)位移測量
土體多點(diǎn)沉降測量
土體分層沉降測量
地基多點(diǎn)位移測量
地基水平位移測量
地基垂直位移測量
自動采集測量數(shù)據(jù)
 
? Strain Gages
? Piezometers
? Water Pressure(Water Level)
? Soil Pressure
? Displacement
? Temperature
? Inclinometers
? Settelment
? Testing Meters
? Calibration Devices
? Datalogger Devices
? Datalogger System
? Cables and Attachments
? Mud-Rock Flow Monitoring System
 
On Jan, 2009, our company has moved to the new address where locates in the city-centre district of Nanjing. The improvement of our working environment will propel the development of our company. Furthermore, the convenient traffics help us to fulfill a better after-sale service. NGN Instrument, Inc. expects your visiting!
 
Products
 

Model VWP Vibrating Wire Piezometer

 

1Application

Model VWP Vibrating Wire Piezometer is applicable to be embedded in hydraulic and other concrete or soil structures to measure the penetrated fluid pressure. Meanwhile, the temperature value of the embedding point can also be measured. By adding accessories, the piezometer can be used for situations like pressure measuring of tunnels, boring for foundation, etc. The piezometer is structured with stainless steel and a dimension of 24x120mm. It can be easily located in narrow and small positions or places. And this piezometer has intelligent identification function..

2Technical Specifications

 

VWP-0.16

VWP-0.25

VWP-0.4

VWP-0.6

VWP-1

VWP-2.5

VWP-3

Size

Outer Diameter D (mm)    

24

Length L (mm)      

120

 

Measurement Range (KPa)

0??160

0??250

0??400

0??600

0??1000

0??2500

0??3000

Performance

Sensitivity k (KPa/F)

??0.072

??0.11

??0.18

??0.27

??0.45

??1.13

??1.35

Accuracy (F.S)

??0.1%

Temp. 1 Measure. 2 Range (??)

-40??+150

Temp. Measure. Accuracy(??)

??0.5

Temp. Correct. 3 Co.4 b (KPa /??)

??0.12

???????  P Water Pressure Resistance (MPa)

1.2 times Measurement Range

Insulation Resistance (M??)

??50

Remark: Frequency Modulus F= Hz2??10-3

1: Temperature

2: Measurement

3: Correction

4: Coefficient

 

3The Theory of Operating

3.1 Constitution

Model VWP Vibrating Wire Piezometer consists of permeable component, induction film, sealed enclosure, signal transmission cable, vibrating wire, excited electromagnetic coil, etc.

3.2 Mechanism

The fluid pressure will generate the deformation of the elastic film. The deformation will be transferred to vibrating wire and to change to be the changing of the strain. Thus, the vibrating frequency of the vibrating wire is changed. The electromagnetic coils excite the vibrating wire and measure the vibrating frequency. The frequency signal is transferred to readout device via the cable. And as the result the pressure value of the fluid load can be obtained. Meanwhile, the temperature value of the embedding point can be measured at the same time.

3.3 Calculation

  a)The pressure value P has a linear relationship with the output frequency modulus ??F as the gauge is bearing the penetrated fluid pressure under environmental temperature as constant:

                             P= k??F

                            ??F = F - F0

where,

k: Sensitivity with the unit of KPa/F;

??F: Difference between the measured real-time value and the reference one with the unit of F;

F: Real-time measured value with the unit of F;

F0: Reference value with the unit of F.

  b)When the penetrated fluid pressure is constant, there is an output value ??F´ if the temperature is increased by ??T. This output is only caused by the changing of the temperature, thus it should be deducted in calculation.

Experiment shows that ??F´ and ??T has the following linear relationship:

                      P´= k??F´+ b??T = 0

                    k??F´= -b??T

                     ??T = T - T0

where,

b: Temperature correction coefficient with the unit of KPa/??;

??T: Difference between the measured real-time value and the reference one with the unit of ??;

T: Real-time measured temperature value with the unit of ??;

T0: Reference temperature value with the unit of ??;

  c)When the gauge is subject to the effects from penetrated fluid pressure and the temperature, it should be corrected if the atmospheric pressure is fairly changed. Thus, the general calculation formula is:

                Pm = k??F + b??T = k (F0 - F) + b(T - T0) + (Q0-Q)

where,

Pm: Strain value of the measured structure with the unit of MPa;

Q0: Reference measured value with the unit of KPa;

Q: Real-time measured value with the unit of KPa;

Meter water column (Unit of pressure) = KPa/9.81

 
?oBack??
 
 

 NGN Instrument, Incorporated Email: njgn@njgn.com 