国产成人无码精品久久久免费_亚洲女精品一区二区三区_海外免费人成视频x8x8在线观看_国内少妇毛片视频

 
混凝土應變的測量
混凝土應力的測量
混凝土溫度的測量
混凝土開合度測量
巖石應變量的測量
鋼筋應力值的測量
滲透水壓力的測量
測壓管水壓力測量
水庫水位值的測量
錨索預應力的測量
靜荷載承壓力測量
結構表面應變測量
結構位移量的測量
結構傾斜量的測量
剛性構件應變測量
土體應變量的測量
土體應力值的測量
土體多點位移測量
土體多點沉降測量
土體分層沉降測量
地基多點位移測量
地基水平位移測量
地基垂直位移測量
自動采集測量數(shù)據(jù)
 
? Strain Gages
? Piezometers
? Water Pressure(Water Level)
? Soil Pressure
? Displacement
? Temperature
? Inclinometers
? Settelment
? Testing Meters
? Calibration Devices
? Datalogger Devices
? Datalogger System
? Cables and Attachments
? Mud-Rock Flow Monitoring System
 
On Jan, 2009, our company has moved to the new address where locates in the city-centre district of Nanjing. The improvement of our working environment will propel the development of our company. Furthermore, the convenient traffics help us to fulfill a better after-sale service. NGN Instrument, Inc. expects your visiting!
 
Products
 

Model VWS-W Vibrating Wire Non-Stressmeter

 

1Application
Model VWS-W Vibrating Wire Non-Stressmeter is applicable to be embedded in hydraulic and concrete geotechnical structures to measure the inner strain value caused by the self-changing of the concrete volume of the structure. Meanwhile, the temperature of the embedding point can be measured. The Non-Stressmeter consists of strain gauge and non-stress bucket. And this Strain Gauge has the intelligent identification function.

2Technical Specifications

 

VWS-10W

VWS-15W

??

Size Parameters

Gauge Length L (mm)     

100

150

Valid Diameter d (mm)    

22

22

End Diameter D (mm)   

33

33

??

Range

Stretching (10-6)

1500

1500

Performance

Compressing (10-6)

1500

1500

Sensitivity k (10-6/F)   

??0.5

??0.5

Accuracy (F.S)     

??0.1%

??0.1%

Temp. 1 Measure. 2 Range (??)

-40??+150

-40??+150

Temp. Measure. Accuracy(??)

??0.5

??0.5

Temp. Correct. 3 Co.4 b (10-6/??)

??13.5

??13.5

modulus of elasticity Eg (MPa)

300??800

300??800

Water Pressure Resistance (MPa)

??1

??1

??

Insulation Resistance (M??)

??50

??50

Remark: Frequency Modulus F= Hz2??10-3

1: Temperature

2: Measurement

3: Correction

4: Coefficient

 

3The Theory of Operating

3.1 Constitution

The Non-Stressmeter consists of strain gauge and non-stress bucket. The bucket is made of two iron sheets and the interlayer is about 8mm-10mm. The bucket is with a circular or cone shape. This bucket is used for isolate the concrete from the strain caused by outside load, but this can measure the strain caused by the self-changing of the concrete volume.

The dimension parameters are:

Small opening: 110 mm;

Larger opening: 220 mm;

Height: 320 mm.

3.2 Mechanism

When the strain is changed from the inner part of the geotechnical structure then the gauge will sense the deformation synchronously. The deformation transfers to the vibrating wire via the front and rear stands and turns out to be the changing of the strain, thus, the vibration frequency of the vibrating wire is changed. Further, the electro-magnetic coils excite the vibrating wire and measure the vibration frequency and the frequency signal is transmitted to the readout device via the cable. As the result, the strain value caused by the self-changing of the concrete volume of the structure can be measured. Meanwhile, the temperature value of the embedding point can be measured at the same time.

3.3 Calculation

   a)The strain value ?? has a linear relationship with the output frequency modulus ??F as the gauge is bearing the axial deformation under environmental temperature as constant:

                             ??= k??F

                            ??F = F - F0

Herewith,

k: Sensitivity with the unit of 10-6/F;

??F: Difference between the measured real-time value and the reference one with the unit of F;

F: Real-time measured value with the unit of F;

F0: Reference value with the unit of F.

   b)When the gauge is not affected by external force (gauge length between both ends is unchanged), there is an output value ??F´ if the temperature is increased by ??T. This output is only caused by the changing of the temperature, thus it should be deducted in calculation.

Experiment shows that ??F´ and ??T has the following linear relationship:

                      ??´= k??F´+ b??T = 0

                    k??F´= -b??T

                     ??T = T - T0

Herewith,

b: Temperature correction coefficient with the unit of 10-6/??;

??T: Difference between the measured real-time value and the reference one with the unit of ??;

, T: Real-time measured temperature value with the unit of ??;

T0: Reference temperature value with the unit of ??;

   c) The gauge settled in the hydraulic or other concrete structures is subject to the effects of deformation and temperature. Then the temperature correction coefficient should be the temperature correction coefficient of the gauge subtracts from the liner expansion coefficient. Thus, the general calculation formula is:

                ??m = k??F + b????T = k (F - F0)+ (b -??)(T - T0)

Herewith,

??m: Strain value of the measured structure with the unit of 10-6;

??: Liner expansion coefficient of the measured structure with the unit of 10-6/??.

 
?oBack??
 
 

 NGN Instrument, Incorporated Email: njgn@njgn.com 
 26 Majiajie street Website: m.hldgxs.cn
 Nanjing, Jiangsu Tel??86(25)84443850/1/2/3
 CHINA 210009 Fax??025-58705973 